Specifications
Mechanical:
42″ diameter x 85″ high (105 x 216 cm)
Weight: 17,000 lbs. (7755 kg) maximum
Power Requirements:
110 or 220 V
50 or 60 Hz
15 amps
Air Supply:
100 PSI minimum, 10 CFM flow
Special Form Co-60 Sources:
• A maximum of 832 TBq (22,500 Curies)
• Three separate source holders with maximum 7,500 Curies of Co-60 in each
Maximum Dose Rate:
• 10 cm diameter sample: 20,000 Gy/hr, 2.0 Mrad/hr +/- 10%
• 20 cm diameter sample: 10,000 Gy/hr, 1.0 Mrad/hr +/- 10%
• See Dose Rate Chart
Sample Chamber:
• 8″ diameter x 12″ high (20 x 30 cm)
• A single 10 RPM turntable motor provides rotation for all turntable positions delivering an integrated dose of +/- 22.5% throughout the chamber
• A one minute exposure is required to integrate the dose to volumetric samples
• Up to three attenuators (X2, X4 & X8 dose rate reduction) can be installed with the full 200 mm diameter x 275 mm high sample
• Stainless steel sample canister: 8″ o.d. x 10″ high (20 x 25 cm)
Access Ports:
• Two maximum @ 35 mm diameter are available
Safety Measures
• External Radiation Levels: The Model 812 has very low external radiation levels, which average < 25 microSv/hr at the surface and < 10 microSv/hr at 30 cm from the surface of the device. Environmental levels at 30 cm are to be less than 5 mR/hr (50 microSv/hr) at all times
• Door Interlocks: The Model 812 system has SEVEN levels of interlocks to prevent accidental exposures. Once the samples are loaded into the exposure chamber, a direct drive actuator closes the access door, and a 500 kg electro-magnet LOCKS the door closed
• Fail-Safe pneumatic source drive with emergency return springs
Control Panel
• 19″ rack mount control panel with Electronic Timer and Preset and Manual operation
• Individual Cobalt 60 Source selection switches
• A 0000.00 minute PRESET timer (manual timing available)
• Keyed power switch with indicator light
• Individual Interlock Switches
◦ On/Off
◦ Beam On switch with indicator light
◦ Beam Off switch with indicator light
◦ Interlocks (closed) indicator lights
◦ Low Air indicator light
◦ Reset switch
• Preset/Manual timer switch
• Emergency OFF switch
Accessories
• Attenuators: X2, X4, X8
• Test Tube Holders
• Animal Holders
• Caustic Acid Vessel
• Heater Assembly
• Dewar